{"product_id":"electric-sterlizer-16-inch-for-surgical-and-examination-instruments","title":"Electric Sterlizer 16 Inch for Surgical and Examination Instruments","description":"\u003ch4 style=\"font-weight: 600;\"\u003ePRODUCT DESCRIPTION\u003c\/h4\u003e\n\u003cp style=\"font-weight: 400;\"\u003eElectric Instrument Sterilizer and Boiler - made of high quality Stainless Steel are used for sterilising and disinfecting surgical instruments. Electric instrument sterilisers have hinged lids and immersion rods.\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eUsage:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eFor sterilizing surgical and examination instruments\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eMade of  304 SS\u003c\/li\u003e\n\u003cli\u003eConsumable\u003c\/li\u003e\n\u003cli\u003eTime saving\u003c\/li\u003e\n\u003cli\u003eEnergy Saving\u003c\/li\u003e\n\u003cli\u003eGreat for reducing of bacteria and viruses\u003c\/li\u003e\n\u003cli\u003eEasy to use\u003c\/li\u003e\n\u003cli\u003eOptimum efficiency\u003c\/li\u003e\n\u003cli\u003eWith Handles for Lid and Base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003ePreparing for usage:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eBefore loading the instruments into the sterilizer ,instruments are thoroughly cleaned .\u003c\/li\u003e\n\u003cli\u003eMake sure that the product used for cleaning the instruments are chloride-free, as certain cleaning agents are highly corrosive and should be avoided.\u003c\/li\u003e\n\u003cli\u003eInstruments are well rinsed to remove all the chemical residues and then well dried prior to the sterilisation process.\u003c\/li\u003e\n\u003cli\u003eCheck the instruments for any signs of damage.\u003c\/li\u003e\n\u003cli\u003eLoad the instruments on the boiler tray, place the heavy instruments at the bottom and smaller instruments at the top, make sure that the hinged instruments such as forceps and scissors are kept open.\u003c\/li\u003e\n\u003cli\u003eDo not overload the boiler tray.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eDirections to use:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003ePlug the instrument steriliser to the main switch .\u003c\/li\u003e\n\u003cli\u003eApprox 1 litre to 1.5 litres of water is put inside the sterilizer\u003c\/li\u003e\n\u003cli\u003eLoad the boiler tray inside the instrument sterilizer\/boiler\u003c\/li\u003e\n\u003cli\u003eMake sure water circulates well among the instruments and all instruments are covered with water.\u003c\/li\u003e\n\u003cli\u003ePut the switch ON and allow the water to boil.\u003c\/li\u003e\n\u003cli\u003eDo not leave the boiler unattended while using it.\u003c\/li\u003e\n\u003cli\u003eAfter the required boiling time , switch OFF the boiler, remove the instruments using cheatle forceps.\u003c\/li\u003e\n\u003cli\u003ePlace the instruments into a sterile metal container and dry them before using with a sterile cloth.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eUser Maintenance:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eAllow the steriliser to cool down and drain the water inside it after every use.\u003c\/li\u003e\n\u003cli\u003eWipe the outside surface of sterilizer with clean cloth everyday.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"font-weight: 400;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eValue\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003egrade 304 SS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking mechanism\u003c\/td\u003e\n\u003ctd\u003eElectrically operated with immersion heater\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Q: What is the sterilizer made of?\\nA: The sterilizer is made of high quality grade 304 stainless steel.\\n\\nQ: How does the sterilizer work?\\nA: The sterilizer is electrically operated with an immersion heater. It heats up the water inside the sterilizer to a high temperature to sterilize surgical and examination instruments.\\n\\nQ: Can any cleaning agent be used to clean the instruments?\\nA: No, it is important to use a chloride-free cleaning agent to clean the instruments, as certain cleaning agents can be highly corrosive and should be avoided.\\n\\nQ: How should I load the instruments into the sterilizer?\\nA: Instruments should be loaded onto the boiler tray with heavier instruments at the bottom and smaller instruments at the top. Hinged instruments, such as forceps and scissors, should be kept open. Do not overload the boiler tray.\\n\\nQ: How much water should be put into the sterilizer?\\nA: Approximately 1 litre to 1.5 litres of water should be put into the sterilizer.\\n\\nQ: How do I know when the sterilization process is complete?\\nA: The sterilization process takes a certain amount of time depending on the instruments being sterilized. The user manual will provide guidelines on the required boiling time. Once the required boiling time is completed, switch off the sterilizer and remove the instruments using cheatle forceps.\\n\\nQ: How should I maintain the sterilizer?\\nA: Allow the sterilizer to cool down and drain the water inside it after every use. Wipe the outside surface of the sterilizer with a clean cloth everyday.\\n\\n\\n\\n\"}' data-sheets-userformat='{\"2\":513,\"3\":{\"1\":0},\"12\":0}'\u003e\u003cstrong\u003eQ: What is the sterilizer made of?\u003c\/strong\u003e\u003cbr\u003eA: The sterilizer is made of high quality grade 304 stainless steel.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: How does the sterilizer work?\u003c\/strong\u003e\u003cbr\u003eA: The sterilizer is electrically operated with an immersion heater. It heats up the water inside the sterilizer to a high temperature to sterilize surgical and examination instruments.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can any cleaning agent be used to clean the instruments?\u003c\/strong\u003e\u003cbr\u003eA: No, it is important to use a chloride-free cleaning agent to clean the instruments, as certain cleaning agents can be highly corrosive and should be avoided.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: How should I load the instruments into the sterilizer?\u003c\/strong\u003e\u003cbr\u003eA: Instruments should be loaded onto the boiler tray with heavier instruments at the bottom and smaller instruments at the top. Hinged instruments, such as forceps and scissors, should be kept open. Do not overload the boiler tray.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: How much water should be put into the sterilizer?\u003c\/strong\u003e\u003cbr\u003eA: Approximately 1 litre to 1.5 litres of water should be put into the sterilizer.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: How do I know when the sterilization process is complete?\u003c\/strong\u003e\u003cbr\u003eA: The sterilization process takes a certain amount of time depending on the instruments being sterilized. The user manual will provide guidelines on the required boiling time. Once the required boiling time is completed, switch off the sterilizer and remove the instruments using cheatle forceps.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: How should I maintain the sterilizer?\u003c\/strong\u003e\u003cbr\u003eA: Allow the sterilizer to cool down and drain the water inside it after every use. Wipe the outside surface of the sterilizer with a clean cloth everyday.\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Q: What is the sterilizer made of?\\nA: The sterilizer is made of high quality grade 304 stainless steel.\\n\\nQ: How does the sterilizer work?\\nA: The sterilizer is electrically operated with an immersion heater. It heats up the water inside the sterilizer to a high temperature to sterilize surgical and examination instruments.\\n\\nQ: Can any cleaning agent be used to clean the instruments?\\nA: No, it is important to use a chloride-free cleaning agent to clean the instruments, as certain cleaning agents can be highly corrosive and should be avoided.\\n\\nQ: How should I load the instruments into the sterilizer?\\nA: Instruments should be loaded onto the boiler tray with heavier instruments at the bottom and smaller instruments at the top. Hinged instruments, such as forceps and scissors, should be kept open. Do not overload the boiler tray.\\n\\nQ: How much water should be put into the sterilizer?\\nA: Approximately 1 litre to 1.5 litres of water should be put into the sterilizer.\\n\\nQ: How do I know when the sterilization process is complete?\\nA: The sterilization process takes a certain amount of time depending on the instruments being sterilized. The user manual will provide guidelines on the required boiling time. Once the required boiling time is completed, switch off the sterilizer and remove the instruments using cheatle forceps.\\n\\nQ: How should I maintain the sterilizer?\\nA: Allow the sterilizer to cool down and drain the water inside it after every use. Wipe the outside surface of the sterilizer with a clean cloth everyday.\\n\\n\\n\\n\"}' data-sheets-userformat='{\"2\":513,\"3\":{\"1\":0},\"12\":0}'\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin :\u003c\/strong\u003e India \u003cbr\u003e \u003cstrong\u003eManufacturer\/Importer\/Marketed By :  \u003c\/strong\u003eMeddey Technologies Pvt Ltd.C-75, First Floor DDA Sheds,Industrial Area , Phase 1 , Okhla , New Delhi - 110020 , Phone No-  +91 8586-012345\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Q: What is the sterilizer made of?\\nA: The sterilizer is made of high quality grade 304 stainless steel.\\n\\nQ: How does the sterilizer work?\\nA: The sterilizer is electrically operated with an immersion heater. It heats up the water inside the sterilizer to a high temperature to sterilize surgical and examination instruments.\\n\\nQ: Can any cleaning agent be used to clean the instruments?\\nA: No, it is important to use a chloride-free cleaning agent to clean the instruments, as certain cleaning agents can be highly corrosive and should be avoided.\\n\\nQ: How should I load the instruments into the sterilizer?\\nA: Instruments should be loaded onto the boiler tray with heavier instruments at the bottom and smaller instruments at the top. Hinged instruments, such as forceps and scissors, should be kept open. Do not overload the boiler tray.\\n\\nQ: How much water should be put into the sterilizer?\\nA: Approximately 1 litre to 1.5 litres of water should be put into the sterilizer.\\n\\nQ: How do I know when the sterilization process is complete?\\nA: The sterilization process takes a certain amount of time depending on the instruments being sterilized. The user manual will provide guidelines on the required boiling time. Once the required boiling time is completed, switch off the sterilizer and remove the instruments using cheatle forceps.\\n\\nQ: How should I maintain the sterilizer?\\nA: Allow the sterilizer to cool down and drain the water inside it after every use. Wipe the outside surface of the sterilizer with a clean cloth everyday.\\n\\n\\n\\n\"}' data-sheets-userformat='{\"2\":513,\"3\":{\"1\":0},\"12\":0}'\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Default Title","offer_id":68335854813315,"sku":"MSH1003440","price":2199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/2844\/9411\/files\/1636121210_electric-sterlizer-for-instruments.jpg?v=1794485735","url":"https:\/\/meddey.in\/products\/electric-sterlizer-16-inch-for-surgical-and-examination-instruments","provider":"Meddey.in","version":"1.0","type":"link"}