AED View Automatic External Defibrilator
In stock
Share this product
Product details
AED View Automatic External Defibrillator for Emergency Response
The AED View Automatic External Defibrillator is an emergency cardiac device designed to support a rapid response during sudden cardiac arrest. It combines multilingual voice prompts, a colour LCD screen and visual indicators to guide users through the defibrillation process. In addition, its adult and pediatric compatibility makes it suitable for different emergency-care environments.
Hospitals, clinics, offices, gyms and public facilities can include this AED as part of an organised emergency response system. Its clear display and voice instructions help communicate the device's prompts during an emergency. However, an AED does not replace professional medical care, CPR training or emergency medical services. Users should follow recognised emergency procedures and the device's instructions.
Introduction to the AED View Defibrillator
The AED View Automatic External Defibrillator is designed to provide guided defibrillation support when a person experiences sudden cardiac arrest. During such emergencies, a rapid response is important. Therefore, an accessible AED can form an important part of a workplace, healthcare facility or public-access emergency plan.
The device features a 3.5-inch colour LCD screen with a resolution of 320 (RGB) x 240. It also provides multilingual voice prompts and LED indicators. Together, these features offer visual and audio guidance during device operation.
Furthermore, the AED supports adult and pediatric configurations. This gives facilities flexibility when preparing emergency equipment for different patient groups. The device uses a biphasic truncated exponential waveform and offers a maximum energy setting of 200 joules, according to the supplied specifications.
Its three-button control layout includes On/Off, Shock and Set buttons. As a result, the main controls remain clearly identified. The AED also analyses the patient's condition before delivering a shock and disables output when patient impedance falls outside the stated operating limits.
Key Features of the AED Machine
1. Adult and Pediatric Compatibility
The AED View is available in adult and pediatric models. This compatibility helps healthcare facilities and emergency-response teams select the appropriate configuration for their intended use. Always check the model, accessories and manufacturer instructions before use.
2. 3.5-Inch Colour LCD Display
The integrated 3.5-inch colour LCD screen displays visual information during operation. Its 320 (RGB) x 240 resolution supports clear on-screen guidance. Additionally, the display works alongside the voice prompts to communicate instructions.
3. Multilingual Voice Prompts
The device offers multiple selectable languages for voice prompts. Consequently, facilities can choose an available language that suits their operating environment. Clear audio instructions can help users follow the device's prompts during a stressful emergency.
4. Biphasic Truncated Exponential Waveform
The AED uses a biphasic truncated exponential waveform. Its specified maximum energy output is 200 joules. The device analyses the patient before shock delivery, and users must follow its prompts and the applicable clinical protocol.
5. Quick Charging Performance
The supplied specifications list charging times for different energy levels. These values describe the stated performance under the specified test conditions. Actual performance can depend on operating conditions, battery condition and device readiness.
6. Three-Button Control System
The control panel includes three buttons: On/Off, Shock and Set. Each button has a defined purpose. Therefore, users can identify the primary controls more easily while following the device's operating instructions.
7. Visual and LED Indicators
The colour LCD and LED indicators provide visual information during operation. In combination with the voice prompts, these indicators help communicate device status and instructions.
Technical Specifications of AED View Defibrillator
The following table summarises the product specifications provided for the AED View Automatic External Defibrillator. These details can help buyers compare the device with their facility's equipment requirements.
| Specification | Details |
|---|---|
| Product Name | AED View Automatic External Defibrillator |
| Models | Adult, Pediatric |
| LCD Screen Size | 3.5 inch |
| LCD Resolution | 320 (RGB) x 240 |
| Waveform | Biphasic truncated exponential |
| Maximum Energy | 200 joules |
| Voice Prompts | Multiple selectable languages |
| Visual Indicators | Colour LCD and LED indicators |
| Analysis Time | 9 seconds |
| Controls | Three buttons: On/Off, Shock and Set |
| Patient Impedance Range | 20Ω to 200Ω |
| Output Safety | Output disabled when patient impedance is outside the stated limits |
AED Charging Time Specifications
Charging performance is an important specification when evaluating an automated external defibrillator. According to the supplied product information, the AED View lists the following charging times under the stated new-device test conditions at 25°C.
| Energy Level | Specified Charging Time |
|---|---|
| 150J | Less than 7 seconds |
| 750J | Less than 3 seconds |
| 200J | Less than 10 seconds |
| 50J | Less than 3 seconds |
Important: The 750J value is reproduced as supplied in the product specifications. Please confirm this figure with the manufacturer before using it in technical or regulatory documentation, as the listed maximum energy is 200J.
Applications of the AED View Automatic External Defibrillator
An AED can support emergency preparedness in locations where people gather, work or receive medical care. The AED View may be considered for suitable facilities that maintain trained responders and an established emergency plan.
Hospitals and Healthcare Facilities
Hospitals and healthcare centres manage patients with different medical needs. An AED can form part of their emergency equipment inventory, subject to the facility's clinical protocols and equipment requirements.
Clinics and Diagnostic Centres
Clinics and diagnostic centres can include an AED in their emergency preparedness arrangements. In addition, staff training and routine equipment checks help ensure that responders understand the correct procedure.
Offices and Commercial Buildings
Workplaces may experience medical emergencies involving employees, visitors or customers. Therefore, an AED can be included in a workplace first-response plan where appropriate training and maintenance arrangements are available.
Gyms and Sports Facilities
Gyms and sports facilities often accommodate people undertaking physical activity. An AED may support their emergency response arrangements. However, staff should also know how to contact emergency services and provide CPR according to their training.
Schools and Public Spaces
Schools, community centres and other public spaces can consider AED placement as part of a wider public-access defibrillation programme. Clear signage, accessible placement, trained responders and regular inspections all contribute to effective preparedness.
Important AED Use and Emergency Response Guidance
An automated external defibrillator is intended to support emergency response during suspected sudden cardiac arrest. If someone collapses, does not respond and is not breathing normally, call emergency services immediately. Start CPR and ask another person to bring the AED, following local emergency guidance.
When the AED arrives, switch it on and follow its voice and visual instructions. Attach the compatible electrodes as directed by the device and its supplied instructions. Ensure nobody touches the patient while the AED analyses the heart rhythm. If the device advises a shock, make sure everyone is clear before following the shock instruction.
After a shock, or if the AED advises no shock, continue CPR as instructed by the device and emergency dispatcher. Keep following the AED prompts until emergency medical professionals take over or the person shows clear signs of recovery.
Safety note: This product description is not a substitute for certified AED and CPR training, the manufacturer's instructions or professional medical advice. Only trained or appropriately instructed responders should operate the device in accordance with applicable local guidance.
AED Maintenance and Readiness Checklist
An AED should remain ready for use whenever a medical emergency occurs. For this reason, facilities should establish a regular inspection schedule and follow the manufacturer's maintenance instructions.
- Check the device's readiness indicator according to the manufacturer's instructions.
- Inspect the AED casing and display for visible damage.
- Check battery status and replace batteries as instructed.
- Check electrode pad expiry dates and packaging condition.
- Confirm that compatible adult and pediatric accessories are available where required.
- Keep the device in an accessible, clearly identified location.
- Train designated staff in CPR and AED procedures.
- Record inspections, maintenance activities and any device-related issues.
Moreover, facilities should never ignore a warning indicator or overdue accessory. Contact the authorised supplier or manufacturer for servicing and replacement guidance when necessary.
What to Consider Before Buying an AED Machine
Choosing an AED requires more than comparing the display size or charging specifications. Buyers should also consider the intended environment, user training, accessory availability and maintenance requirements.
1. Intended Use
First, identify where the device will be installed. A hospital, workplace, gym and public facility may have different emergency response requirements. Therefore, confirm that the selected model suits the intended application.
2. Adult and Pediatric Requirements
Check whether the selected model supports the required patient groups. Also confirm the compatible pediatric accessories and the manufacturer's instructions for their use.
3. Display and Voice Guidance
A clear display and understandable voice prompts can support device operation. In addition, check the available languages and confirm that they suit the intended users.
4. Battery and Electrode Availability
Before purchasing, ask about battery replacement, electrode pad availability, expiry periods and compatible accessories. These items are important for long-term readiness.
5. Training and After-Sales Support
Finally, check the availability of user training, technical support and authorised servicing. A suitable maintenance plan helps the facility keep the AED ready for emergency use.
Frequently Asked Questions About AED View Defibrillator
Q1. Is the AED View suitable for pediatric emergencies?
Answer: The supplied product information lists adult and pediatric models. However, buyers should confirm the exact model and compatible pediatric accessories before use. Always follow the manufacturer's instructions and applicable emergency-care guidance.
Q2. What is the LCD screen size of this AED machine?
Answer: The AED View features a 3.5-inch colour LCD screen with a resolution of 320 (RGB) x 240. It provides visual information alongside the device's voice prompts.
Q3. Does the AED provide multilingual voice prompts?
Answer: Yes. The product specifications mention multiple selectable languages for voice prompts. Available language options should be confirmed with the supplier before purchase.
Q4. What waveform does the AED View use?
Answer: The supplied specifications identify a biphasic truncated exponential waveform. The listed maximum energy is 200 joules.
Q5. What is the analysis time of the AED?
Answer: The specified analysis time is 9 seconds. Actual operation should always follow the device's prompts and the manufacturer's instructions.
Q6. How many buttons does the AED have?
Answer: The device has three buttons: On/Off, Shock and Set. These controls support the device's basic operating functions.
Q7. Does the AED monitor patient impedance?
Answer: Yes. The supplied specifications state that the device disables output when patient impedance falls outside the stated range of 20Ω to 200Ω.
Q8. What is the maximum energy output?
Answer: The listed maximum energy is 200 joules. Buyers should refer to the official technical documentation for complete operating details.
Q9. Can this AED be used in offices and gyms?
Answer: The product is described for emergency response in environments such as offices and gyms. However, facilities should establish an appropriate emergency plan, provide responder training and maintain the device correctly.
Q10. Does an AED replace CPR?
Answer: No. An AED works alongside CPR during sudden cardiac arrest response. Call emergency services, begin CPR and follow the AED's instructions until professional help takes over.
Q11. What should buyers check before ordering?
Answer: Buyers should confirm the selected model, adult or pediatric compatibility, included accessories, battery and electrode availability, warranty terms and after-sales support.
Q12. Where should an AED be stored?
Answer: Keep the AED in a visible, accessible location that follows the manufacturer's storage requirements. Also ensure that staff know its location and that routine readiness checks take place.
Product and Manufacturer Information
Product Name: AED View Automatic External Defibrillator
Country of Origin: India
Manufacturer / Importer / Marketed By: Meddey Technologies Pvt Ltd.
Address: C-75, First Floor, DDA Sheds, Industrial Area, Phase 1, Okhla, New Delhi - 110020
Contact Number: +91 8586-012345
Choose AED View for Emergency Preparedness
The AED View Automatic External Defibrillator combines a colour LCD display, multilingual voice prompts, LED indicators and a three-button control system. Its adult and pediatric model options provide flexibility for different emergency-response settings. Therefore, healthcare facilities and organisations can evaluate this AED as part of their emergency equipment planning. Before ordering, confirm the model, accessories, technical specifications, warranty and service arrangements with the supplier. Most importantly, ensure that intended users receive appropriate CPR and AED training.
Same category
CPR Training
PRESTAN AED UltraTrainer for CPR & AED Training






























